-
Products
- Adjustment tools
- Bench center
- Bevel and steel protractor
- Caliper gauge
- Certification
- Checking mandrel
- Control caliper
- Depth caliper
- Depth micrometer
- Dial caliper
- Dial indicator
- Digital pocket calipers
- Digital scale unit
- Digital universal caliper
- Gauge blocks
- Gauges
- Hardness tester / Shore durometer
- Height and marking gauges
- Inside groove vernier caliper
- Inside micrometer
- Internal measuring instrument
- Inside and outside calipers
- Knife straight edges
- Limit plug gauges DIN 2245
- Limit thread gauges
- Magnifier / Lamps
- Magnetic dial supports
- Master squares 90°
- Measuring tools with certificate
- Measuring adapter and inserts for caliper
- Measuring balls
- Measuring cylinder 90°
- Measuring tapes
- Measuring tool sets
- Microscopes
- Micrometer head
- Nut and bold thread checker sets
- Outside micrometer analog
- Outside micrometer digital
- Outside micrometer with counter
- Pin gauges
- Plane glass for inspection of flatness
- Precision measuring table, granit plates and cast iron plates
- Precision toolmarkers vise
- Ratchet force measuring tool
- Setting ring gauges DIN 2250
- Setting ring gauges, made of ceramic
- Setting standard for micrometer
- Steel marking
- Steel ruler
- Steel parallels and V-blocks
- Special caliper
- Spirit levels and digital levels
- Squares
- Surface checking plates
- Thickness gauges
- Thread ring gauges
- Three point internal micrometer
- Torque wrench
- Universal measuring table with digital micrometer head
- Universal Test Indicator
- USB - Interfaces
- Vernier caliper analog
- Video-inspection-endoscopes
- Special offer
- New items
- Werka measuring tools
- Download / Catalogues
- Contact
- Our other webshops
Setting standard for outside micrometer
Setting standard 100 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 2,5 µm D Ø: 8 mm Range: 100 mm
Setting standard 1050 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 12 µm D Ø: 16 mm Range: 1025 mm
Setting standard 1150 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 12 µm D Ø: 16 mm Range: 1075 mm
Setting standard 125 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 2,5 µm D Ø: 8 mm Range: 125 mm
Setting standard 150 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,0 µm D Ø: 8 mm Range: 150 mm
Setting standard 175 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,0 µm D Ø: 8 mm Range: 175 mm
Setting standard 200 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,5 µm D Ø: 8 mm Range: 200 mm
Setting standard 225 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,5 µm D Ø: 8 mm Range: 225 mm
Setting standard 25 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 2 µm D Ø: 7 mm Range: 25 mm
Setting standard 250 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,5 µm D Ø: 8 mm Range: 250 mm
Setting standard 275 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 3,5 µm D Ø: 8 mm Range: 275 mm
Setting standard 325 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 4 µm D Ø: 16 mm Range: 325 mm
Setting standard 375 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 4 µm D Ø: 16 mm Range: 375 mm
Setting standard 425 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 5 µm D Ø: 16 mm Range: 425 mm
Setting standard 475 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 5 µm D Ø: 16 mm Range: 475 mm
Setting standard 50 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 2 µm D Ø: 7 mm Range: 50 mm
Setting standard 525 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 6 µm D Ø: 16 mm Range: 525 mm
Setting standard 575 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 6 µm D Ø: 16 mm Range: 575 mm
Setting standard 625 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 7 µm D Ø: 16 mm Range: 625 mm
Setting standard 675 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 7 µm D Ø: 16 mm Range: 675 mm
Setting standard 725 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 8 µm D Ø: 16 mm Range: 725 mm
Setting standard 75 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - flat measuring faces Accuracy: ± 2 µm D Ø: 7 mm Range: 75 mm
Setting standard 775 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 8 µm D Ø: 16 mm Range: 775 mm
Setting standard 825 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 9 µm D Ø: 16 mm Range: 825 mm
Setting standard 875 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 9 µm D Ø: 16 mm Range: 875 mm
Setting standard 925 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 10 µm D Ø: 16 mm Range: 925 mm
Setting standard 975 mm for outside micrometers - for the calibration of outside micrometers - with heat insolation - round measuring faces Accuracy: ± 10 µm D Ø: 16 mm Range: 975 mm